Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Indian Heart J ; 1999 Mar-Apr; 51(2): 167-72
Article in English | IMSEAR | ID: sea-5645

ABSTRACT

Primary angioplasty has been shown to reduce rates of in-hospital mortality, recurrent ischaemia and infarction. However, the role of primary stenting and abciximab is presently undergoing evaluation. This study attempted to examine the feasibility, safety and outcomes of primary angioplasty in the treatment of acute myocardial infarction. Data in 100 patients who underwent primary angioplasty for evolving acute myocardial infarction was prospectively analysed to assess the safety and efficacy of various modalities. Twenty patients were in Killip class III and above. Multivessel (2 or more vessels) disease was noted in more than 52 cases. Procedural success was 99 percent; 86 patients received primary stenting, majority of them had Kalam-Raju stent implantation. Adjunct treatment included abciximab infusion in 22 and intra-aortic balloon pump support in 12. Overall mortality rate was six percent with a mortality of 2.2 percent in non-cardiogenic shock patients. Recurrent ischaemic events were noted in five, three of them had successful reperfusion with repeat angioplasty. None of the patients had emergency coronary artery bypass surgery. It is concluded that primary angioplasty is safe and effective with high procedural success. Recurrent ischaemic events are low, possibly due to routine use of stenting and selective use of abciximab.


Subject(s)
Adult , Angioplasty, Balloon, Coronary , Antibodies, Monoclonal/therapeutic use , Anticoagulants/therapeutic use , Coronary Angiography , Feasibility Studies , Female , Hemodynamics , Humans , Immunoglobulin Fab Fragments/therapeutic use , Male , Middle Aged , Myocardial Infarction/physiopathology , Prospective Studies , Recurrence , Stents , Treatment Outcome
2.
Indian Heart J ; 1998 Jan-Feb; 50(1): 40-4
Article in English | IMSEAR | ID: sea-3806

ABSTRACT

The purpose of this study was to determine the feasibility, safety and efficacy of elective deployment of a new coil-stent (KR stent) in patients with coronary artery disease. KR stent deployment was attempted in 100 patients (135 lesions) enrolled prospectively at a single centre from December 1996 to March 1997. Ten, 15, 18, 24, and 32 mm long KR stents were manually crimped onto balloons and deployed in native coronary artery lesions. Majority of the patients had recent acute coronary syndromes (unstable angina 30% and post-myocardial infarction angina 56%). Diabetes was present in 34 percent of the patients. Fifty-six percent had single-vessel and 44 percent multi-vessel disease. In 38 percent, the lesions were located in proximal segments and 40 percent of lesions were long. KR stents were successfully deployed in 98 percent of patients. Mean minimal luminal diameter increased by 2.89 +/- 0.63 mm (from 0.57 +/- 0.38 mm before to 3.45 +/- 0.56 mm after the procedure). Mean percent diameter stenosis decreased from 83.33 +/- 10.84 percent before to 3.38 +/- 5.74 percent after the stent deployment. Mean reference vessel diameter was 3.45 +/- 0.56 mm. There were occasional technical complications including balloon rupture (1), stent migration (2) and distal embolisation of atheromatous material (1). One patient developed subacute stent thrombosis. There were no other major in-hospital cardiovascular events. At the end of six-month follow-up, there were no myocardial infarction or death. Six patients presented with recurrence of symptoms within six-months of the procedure, four of whom underwent target vessel revascularisation procedure. In conclusion, the in-hospital and six-month follow-up clinical results were highly encouraging with KR stent. Successful deployment rates were high despite unfavourable clinical and angiographic background. Low clinical events on follow-up will make it suitable for elective stenting.


Subject(s)
Adult , Aged , Angioplasty, Balloon/adverse effects , Coronary Angiography , Coronary Disease/mortality , Equipment Design , Equipment Safety , Female , Follow-Up Studies , Hospital Mortality , Humans , India , Male , Middle Aged , Prospective Studies , Stents/adverse effects , Survival Rate , Treatment Outcome , Vascular Patency/physiology
3.
Indian J Pediatr ; 1987 Mar-Apr; 54(2): 219-28
Article in English | IMSEAR | ID: sea-80515
4.
Indian J Pediatr ; 1987 Mar-Apr; 54(2): 237-43
Article in English | IMSEAR | ID: sea-80370
SELECTION OF CITATIONS
SEARCH DETAIL